Jandy

R0479500

Jandy Flopro Seal Plate Kit R0479500

$115.00
Shipping calculated at checkout.
Fast shipping
Ships in 2 to 3 business days

Pickup available at Marathon FL

Usually ready in 24 hours

View Specifications
Product Description

Jandy FloPro Seal Plate Kit R0479500 | Genuine OEM Backplate & Seal Replacement

Restore peak pump performance with the genuine Jandy FloPro Seal Plate Kit (R0479500)! This complete OEM replacement kit includes the backplate, all necessary mechanical seals, O-ring, bolts, and washers for a secure, leak-proof repair. Designed specifically for Jandy FloPro FHPM Series pumps, it ensures proper sealing and reliable operation, making pump maintenance straightforward and effective.

  • Genuine OEM Part: Manufactured by Jandy/Zodiac for guaranteed compatibility and performance with FloPro pumps.
  • Complete Repair Solution: The all-in-one kit includes the backplate, both carbon and ceramic mechanical seals, backplate O-ring, and all necessary bolts and washers for a full replacement.
  • Ensures Proper Sealing: High-quality components help prevent leaks, restore prime, and maintain efficient water circulation.
  • Durable Construction: Built from robust materials designed to withstand typical pool pressures, heat, and chemical exposure.
  • Broad Compatibility: Specifically designed to fit all models within the Jandy FloPro FHPM and VS FloPro series pumps.
  • Simplifies Maintenance: Provides all required hardware in one package, streamlining the repair process and minimizing downtime. 

Specifications

Specifications

Product Name Jandy FloPro Seal Plate Kit
Part Number R0479500
Pump Series Jandy FloPro (FHPM)
Components Backplate, O-Ring, Mechanical Seal, Hardware
VS Model Compatibility VS-FHP1.0, 1.65, 1.85, 2.0, 2.7, 3.8
Seal Material Carbon and Ceramic
Hardware Material Stainless Steel
Origin United States (OEM)

Warnings and Disclaimers

  • Electrical Hazard: Always disconnect power at the circuit breaker before servicing. Failure to do so may result in severe injury or death.
  • Pressure Hazard: Relieve all system pressure before installation. Do not exceed 35 PSI during subsequent pressure tests.
  • Air Entrapment: Ensure all air is bled from the system before operation to prevent high-pressure lid displacement.
  • Disclaimer: Professional installation by a licensed technician is highly recommended. Compatibility must be verified via the pump serial number or model.

Application & Pro-Tips

  • Seal Handling: Never touch the polished faces of the carbon or ceramic seals with your fingers, as oils can cause premature failure.
  • O-Ring Care: Use a water-based lubricant (e.g., Magic Lube) on the backplate O-ring. Avoid petroleum-based products which can degrade the rubber.
  • Torque Pattern: Tighten the six backplate bolts in a "star" or cross-pattern to ensure even pressure and prevent the plate from warping or cracking.
  • Inspection: Check the impeller and diffuser for wear while the pump is open; replacing these alongside the seal plate can restore original flow performance.
  • Leak Prevention: Ensure the ceramic seal is seated perfectly flush in the backplate before reattaching to the motor.