Restore peak pump performance with the genuine Jandy FloPro Seal Plate Kit (R0479500)! This complete OEM replacement kit includes the backplate, all necessary mechanical seals, O-ring, bolts, and washers for a secure, leak-proof repair. Designed specifically for Jandy FloPro FHPM Series pumps, it ensures proper sealing and reliable operation, making pump maintenance straightforward and effective.
- Genuine OEM Part: Manufactured by Jandy/Zodiac for guaranteed compatibility and performance with FloPro pumps.
- Complete Repair Solution: The all-in-one kit includes the backplate, both carbon and ceramic mechanical seals, backplate O-ring, and all necessary bolts and washers for a full replacement.
- Ensures Proper Sealing: High-quality components help prevent leaks, restore prime, and maintain efficient water circulation.
- Durable Construction: Built from robust materials designed to withstand typical pool pressures, heat, and chemical exposure.
- Broad Compatibility: Specifically designed to fit all models within the Jandy FloPro FHPM and VS FloPro series pumps.
- Simplifies Maintenance: Provides all required hardware in one package, streamlining the repair process and minimizing downtime.
Specifications
Warnings and Disclaimers
- Electrical Hazard: Always disconnect power at the circuit breaker before servicing. Failure to do so may result in severe injury or death.
- Pressure Hazard: Relieve all system pressure before installation. Do not exceed 35 PSI during subsequent pressure tests.
- Air Entrapment: Ensure all air is bled from the system before operation to prevent high-pressure lid displacement.
- Disclaimer: Professional installation by a licensed technician is highly recommended. Compatibility must be verified via the pump serial number or model.
Application & Pro-Tips
- Seal Handling: Never touch the polished faces of the carbon or ceramic seals with your fingers, as oils can cause premature failure.
- O-Ring Care: Use a water-based lubricant (e.g., Magic Lube) on the backplate O-ring. Avoid petroleum-based products which can degrade the rubber.
- Torque Pattern: Tighten the six backplate bolts in a "star" or cross-pattern to ensure even pressure and prevent the plate from warping or cracking.
- Inspection: Check the impeller and diffuser for wear while the pump is open; replacing these alongside the seal plate can restore original flow performance.
- Leak Prevention: Ensure the ceramic seal is seated perfectly flush in the backplate before reattaching to the motor.