Taylor
DPD Reagent #1 R-0001
Pickup available at Marathon FL
Usually ready in 24 hours
Product Description
The R-0001 DPD Reagent #1 is the primary liquid indicator used in professional-grade water testing to measure Free Available Chlorine (FAC). As the first step in any chlorine analysis, this reagent provides the most critical data point for ensuring your pool or spa is safe, sanitary, and free of bacteria.
Key Product Features
- Instant Reaction: Provides an immediate pink-to-red color shift when added to chlorinated water, allowing for rapid field testing.
- High-Resolution Results: Specifically formulated to work with standard color comparators to provide accurate parts-per-million (PPM) readings.
- Precision Dropper Tip: Engineered to deliver uniform drop sizes (standard 5-drop dosage) for consistent and repeatable test cycles.
- Light-Shielded Protection: Packaged in opaque white bottles to prevent UV-induced oxidation and extend the chemical's active shelf life.
Specifications
The primary liquid indicator used in professional-grade water testing to measure Free Available Chlorine (FAC). As the first step in any chlorine analysis, this reagent provides the most critical data point for ensuring your pool or spa is safe, sanitary, and free of bacteria.
| Part Number | Individual Volume | Quantity | Total Drops (Approx.) |
|---|---|---|---|
| R-0001-A-1 | 0.75 oz (22 mL) | 1 Bottle | 440 Drops |
| R-0001-C-12 | 2.0 oz (60 mL) | 12 Bottles (Bulk Case) | ~14,400 Drops |
⚠️ Reagent Safety & Handling Warnings
- The Vertical Drop: Hold the bottle perfectly vertical. Tilted bottles produce smaller drops, leading to a "false-low" chlorine reading.
- The "Flash" Effect: If chlorine is above 10 ppm, the sample may turn red and then instantly go clear. This is "bleach out." Dilute with distilled water and re-test.
- Protocol: Fill vial to line, add 5 drops of R-0001, cap, and swirl. Match against comparator block standards immediately.