{"product_id":"7-5uf-7-5-mfd-370vac-440vac-450vac-50-60hz-cbb65b-round-run-start-capacitor-for-ac-unit-fan-motor-start-or-pool-pump-or-air-condenser-straight-cool","title":"7.5 MFD 370\/440V Round Fan Capacitor - Replacement for Jandy R0936300 (VersaTemp JRT)","description":"\u003cdiv\u003e \u003cdiv\u003e \u003ch2\u003eProduct description\u003c\/h2\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003ch3\u003e VEXUNGA Run Start Air Conditioner Capacitor \u003c\/h3\u003e \u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThis capacitor is used for start-up and operation of\u003cspan\u003e one-way motors\u003c\/span\u003e, such as Motor Run or Heat Pump Air Conditioner or Condenser Straight Cool.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThis kind of capacitor uses polypropylene film (thickened by zinc and aluminum ) as medium, coiling by Automatic winding machine, Packaged plastic shell, filling epoxy, Made Capacitors with good sealing, insulation performance, self-healing, low loss, low inherent temperature rise, stable performance, good reliability and longer life.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir conditioner capacitor is \u003cspan\u003esmall \u003c\/span\u003ein size, \u003cspan\u003elightweight\u003c\/span\u003e, \u003cspan\u003eheat resisting\u003c\/span\u003e and \u003cspan\u003eanti-explosion\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eCapacitors come in a variety of sizes, but depending on the capacitance (µF or MFD) and the voltage.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eVEXUNGA Air Conditioner Capacitor is A Good Choice !!!\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003ch3\u003e SPECIFICATIONS: \u003c\/h3\u003e \u003cul\u003e\n\u003cli\u003e\u003cspan\u003eModel: \u003cspan\u003eCBB65B \u003c\/span\u003e（Universal model）\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: \u003cspan\u003e-40℃ to +70℃\/-104℉ to +158℉\u003c\/span\u003e. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFrequency: \u003cspan\u003e50\/60 Hz\u003c\/span\u003e. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating Life: \u003cspan\u003e60,000 hours with 94% survival\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDissipation Factor: \u003cspan\u003e0.1% maximum\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApplicable to the frequency of 50hz \/ 60hz ac power supply \u003cspan\u003eone-way motor\u003c\/span\u003e starting and running, and it is widely used for pool pump, washing machine, cleaning machine, single phase electric motor, air compressor as starting and running.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCapacitor has \u003cspan\u003etwo terminals\u003c\/span\u003e on the top.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003ch3\u003e \"WHEN” to Replace AC Capcitor \u003c\/h3\u003e \u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- The air conditioner's \u003cspan\u003efan \u003c\/span\u003ewouldn't spin - \u003cspan\u003estopped working\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- The air conditioner \u003cspan\u003ehummed\u003c\/span\u003e, but no air flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- The ac fan would spin intermittingly and the external pump would\u003cspan\u003e not start\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- The air conditioner \u003cspan\u003estopped cooling\u003c\/span\u003e - the compressor in the condenser maybe not coming on.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- As the capacitor \u003cspan\u003egets older\u003c\/span\u003e, the motor may get louder and seem to \u003cspan\u003erun slower\u003c\/span\u003e. You can extend the life of your motor if you \u003cspan\u003ereplace \u003c\/span\u003ethem \u003cspan\u003ebefore \u003c\/span\u003ethey become weak. Eventually the capacitor will become too \u003cspan\u003eweak \u003c\/span\u003eto start the motor, and if the motor won't start it may be shorted. \u003cspan\u003eTimely replacement of capacitors is crucial to air conditioner maintenance\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003ch3\u003e \"VERY EASY” to Replace AC Capcitor \u003c\/h3\u003e \u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFirst of all,\u003cspan\u003e Turn off\u003c\/span\u003e the power to the air conditioner.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecondly, \u003cspan\u003eTake out\u003c\/span\u003e the ac capacitor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinally, \u003cspan\u003eMake sure\u003c\/span\u003e that you know which wire is for which terminal - direct replacement without changing wiring or adapters \u0026amp; \u003cspan\u003eConfirm \u003c\/span\u003ethe appropriate capacitance (µF or MFD) and voltage.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWhat's important, \u003cspan\u003eReplace \u003c\/span\u003eair conditioner capacitor by yourself that will save you a lot of \u003cspan\u003emoney \u003c\/span\u003eand \u003cspan\u003etime\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cul\u003e\u003cli\u003e\u003cspan\u003ePackage contains 1piece x VEXUNGA 7.\u003cspan\u003e\u003cspan\u003e5uF 7.5 MFD 37\u003c\/span\u003e\u003c\/span\u003e0\/440\/450 VAC Run Start Round AC Capacitor.\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cul\u003e\n\u003cli\u003eVEXUNGA 7.5uF ±6% 370\/440\/450 VAC CBB65 round run start capacitor replacement for ALL 250 \u0026amp; 300 \u0026amp; 370 \u0026amp; 440 \u0026amp; 450 Volt capacitors.\u003c\/li\u003e\n\u003cli\u003e7.5 MFD Capacitor size measures (1.57inch \/ 40mm) in Diameter x (2.16inch \/ 55mm) in Height.\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -40℃ to +70℃\/-104℉ to +158℉. Frequency: 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003eApplicable to the frequency of 50hz \/ 60hz ac power supply one-way motor starting and running, and it is widely used for pool pump, washing machine, cleaning machine, single phase electric motor, air compressor as starting and running.\u003c\/li\u003e\n\u003cli\u003eSUPER EASY to Replace: Direct replacement, no wiring or adapter changes required. Capacitor has two terminals on the top.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Generic","offers":[{"title":"7.5Uf Round","offer_id":68068452335932,"sku":"0ad32a69-aa8f-4b20-8328-18d7ac4cf3c9","price":13.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0925\/0252\/4220\/files\/0b3b11902580fd9113cad018d7ccb455.jpg?v=1793651771","url":"https:\/\/msppool.com\/products\/7-5uf-7-5-mfd-370vac-440vac-450vac-50-60hz-cbb65b-round-run-start-capacitor-for-ac-unit-fan-motor-start-or-pool-pump-or-air-condenser-straight-cool","provider":"MSP Supply","version":"1.0","type":"link"}